A fluorine lined valve acts as a primary barrier against corrosive process fluids. However, even small flaws in the lining can lead to severe system damage or leaks, often called “holidays or pinholes.” These defects, often microscopic gaps from manufacturing, mechanical stress, or thermal cycling, compromise the valve’s structural integrity.
By explaining the standard methods used to inspect valve linings, like spark test and holiday test, this guide explains how to identify these defects to ensure system integrity.

Understanding the distinction between spark testing and holiday testing is vital for ensuring coating integrity, preventing corrosion, and avoiding expensive failures of a lined ball valve. Below is a comprehensive comparison of the two.

The spark testing is typically used to check pinholes, voids, and discontinuities in surface coatings. A voltage is applied through metal fibers placed on the coated surface. When a defect is present, the circuit closes, and a spark indicates the flaw.
Inspectors carefully apply voltage because of safety risks and coating thickness requirements. Testing begins at a low voltage and slowly increases until the accurate current level is reached. With higher voltage settings, coatings up to 25mm thick can be effectively tested.
Two types of spark testers:
When to use spark testing:
A holiday is also a defect in the coating, such as pinholes, gaps, cracks, and thin spots, that exposes the substrate. Below are the reasons why holiday testing is important:
The following are the timelines when you can perform holiday testing:
Common Tool for Holiday Testing: Wet Sponge / Low-voltage Detector
| Features | Spark Testing | Holiday Testing |
| Meaning | A particular method that uses high voltage to detect coating defects. | A general method to find any defect in a coating. |
| Working Operation | High voltage jumps (sparks) through the defect to alarm and visible spark. | High voltage jumps (sparks) through the defect to alarm and a visible spark. |
| Best For | Thick protective coatings and linings. | Thin coatings or paint layers. |
| Voltage Used | Always high voltage. | Current flows through a defect to the detector alerts. |
| Coating Thickness | 500 microns to several millimeters. | Up to approximately 500 microns (low-voltage). |
| Coverage Area | 100% surface coverage with visual confirmation. | Low or high, depending on coating thickness. |
| Risk | Needs trained operators to set the voltage correctly. | Good coverage, but it depends on the method. |
| Operator Skill | Easy for beginners (particularly the wet sponge method). | Very low risk when the voltage is accurate. |
| Common Tools | AC spark tester & DC holiday detector | Wet sponge detector, low-voltage detector. |
| Common Uses | Pipelines, geomembranes, tank linings, and heavy-duty protective coatings | Paint coatings, small jobs, and waterproof layers. |
Testing needs a dedicated detector unit, including a power source, a probe, and a grounding cable. The probe usually consists of a soft brush or a conductive coil that allows the operator to reach into complex shapes like valve ports. Meanwhile, the grounding cable must have a solid and clean connection to the valve body.
Modern units provide precise voltage adjustment and digital current monitoring. Moreover, probes must remain clean to avoid false readings, as worn or dirty brushes may miss defects. Proper maintenance ensures consistent inspection results.
Preparation is the most essential step in the testing process. The valve interior must be clean and completely dry, as moisture or chemical residue may lead to false readings. A dry surface ensures the spark occurs only at actual defects.
Conduct the test in a well-lit, controlled setting and steadily move the probe to cover the entire surface. Ensure to also follow the manufacturer’s guidelines for voltage and probe speed to avoid missing small discontinuities.
Moreover, make sure to record all inspection results and clearly mark any defects. Minor flaws can be repaired, but major damage typically needs liner replacement. Therefore, it is essential to keep records of test dates and voltage settings for traceability.
Ultimately, always follow safety procedures when handling high-voltage equipment. Wear insulating gloves and ensure proper grounding to avoid electrical hazards.
The spark and holiday tests are essential for verifying the protective layer of fluorine lined valves. These tests use electrical conductivity to identify defects in the liner, preventing corrosion and extending the equipment’s service life. Regardless, regular maintenance based on these tests is important for any chemical process line.
Lianke maintains rigorous quality standards through our in-house testing procedures. Our wide-range of fluorine lined valves integrate full body cavity lining of fluoroplastics, providing corrosion resistance to acids and organic chemicals. Operating from -29°C to 180°C, our products provide long service life, low leakage risk, and reliable handling of hazardous media.
Discover our strict quality control and state-of-the-art facilities ensuring the highest standard for every valve.
Explore Process
PP pinch valve, as the name suggests, is a pinch valve of PP shell material. The main advantage of this valve is that the valve body is made of pp plastic, so the valve body is lighter and can be installed on the suspended pipe. PP material has the characteristics of acid and alkali resistance […]
Basket strainers are essential pipeline pre-filtration equipment widely used in chemical processing, water treatment, petroleum, food & beverage, pharmaceutical and general manufacturing. Industrial fluid pipelines are critical to stable production, yet process water, oil and chemical media often carry sediment, rust, solid particles and material agglomerates. These tiny contaminants cause pump abrasion, valve blockage, heat exchanger […]
In 2026, Lianke Valve marks the 25th national Work Safety Month. Centered on the theme “Guard the bottom line by addressing minor risks; build safety through rigorous inspection and rectification”, Lianke Valve has fully launched a special work safety campaign. By implementing a full range of activities including thematic briefings, emergency drills and hazard inspections, […]
As intense summer heatwaves continue, persistently high temperatures have brought severe challenges to frontline workshop operations. To effectively conduct heatstroke prevention work and protect the physical and mental health of all employees, Lianke has launched the annual Summer Cool Relief employee care campaign. Honoring Dedication with Sincere Care The company has distributed daily-use laundry detergent […]